Fisher DST-G Trim
Fisher DST-G trim is designed for clean or dirty services where dissolved gases are released due to a pressure reduction (outgassing), helping reduce damage mechanisms such as cavitation and erosion. It uses staged pressure drop plus a special slotted lower cage to break the stream into smaller, lower-energy jets—minimizing wear and improving service life.
Key Features
•Built for outgassing services with dissolved gas release.
•Staged pressure drop to help prevent cavitation.
•Slotted lower cage to reduce erosion from entrained gas.
•Suitable for dirty service scenarios (final suitability depends on actual process conditions).
Specifications
| specifications | details |
|---|---|
| Critical Service | Outgassing, Dirty Service |
| Material | Carbon Steel, Stainless, Alloy |
| Operating Temperature | Standard Temperature |
| Pressure Class | ASME |
| Process Connection Type | Flanged |
| Shutoff Class | Class V (FCI 70-2) |
| Valve Size | NPS 2, NPS 3, NPS 4, NPS 6, NPS 8, NPS 10, NPS 2×3, NPS 3×4, NPS 6×8 |
| Valve Size Standard | NPS |
| Other Configurations | Contact your local Emerson business partner or sales office to learn about additional specifications or options for this product. |
Selection Guide
Please share fluid composition, P1/P2 & T1/T2, ΔP, flow range, line size, end connection, and any requirements for shutoff class/actuator/positioner so we can size and configure correctly.
Applications
Commonly used in separator letdown and other severe services prone to outgassing + cavitation/erosion.
Project Support
We can support sizing & configuration, project documentation alignment (datasheet/inspection docs/cert needs), and provide a stable delivery plan subject to order confirmation and availability.
FAQ
•DST-G vs. DST—what’s the difference?DST-G adds a slotted lower cage to better control erosion from entrained gas while staging the pressure drop.
•Is it suitable for dirty service?It can be, but we must confirm with solids content/size and process details.
•What do you need for a quote?Process conditions + size/class/ends + desired configuration (actuator/positioner).
Contact CTA
Send your datasheet/process conditions—we’ll propose the right configuration, lead time, and a competitive quote.

Rosemount
Gauge Pressure
Differential Pressure
Absolute Pressure
Rosemount Level Transmitter
Yokogawa
ABB
E+H
HoneyWell
Micro Motion Coriolis
Rosemount
Yokogawa
E+H





Valves&Actuators
Reviews
There are no reviews yet.