Description
Part Number: 3051CG4A02A1AH2B3I1M5HR5
- Power advisory can proactively detect degraded electrical loop integrity issues(option code DA0)
- LOI with straightforward menus and built-in configuration buttons (option code M4)
- Safety Certification (option code QT)
Ordering Information
| Model | 3051C(1) | Coplanar Pressure Transmitter |
| Measurement type | G | Gage |
| Pressure range | 4 | –14.2 to 300 psi (-0,97 to 20,68 bar) |
| Transmitter output | A(2) | 4 – 20 mA with Digital Signal Based on HART Protocol |
| Materials of construction | 0 | Alternate Process Connection |
| Isolating diaphragm | 2(3) | 316L SST |
| O-ring | A | Glass-filled PTFE |
| Sensor fill fluid | 1 | Silicone |
| A | Housing material: Aluminum Conduit entry size: ½–14 NPT |
|
| Alternate flange(4) | H2 | Traditional Flange, 316 SST, SST drain/vent |
| Mounting bracket(5) | B3 | Traditional flange flat bracket, CS, 2-in. pipe |
| Product certifications | I1(6) | ATEX Intrinsic Safety and Dust |
| Display and interface options | M5 | LCD Display |
| HART Revision configuration (requires HART Protocol Output Code A) | HR5(7) | Configured for HART Revision 5 |
- Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
- Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to
HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output. - Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. - Requires 0 code in Materials of Construction for Alternate Process Connection.
- Panel mounting bolts are not supplied.
- Dust approval not applicable to Output Code X. See “IEC 62591 (WirelessHART Protocol)” on page 62 for wireless approvals.
- Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to
HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
- Estimated Lead Time: 8 – 10 Weeks