Description
Yokogawa YTA110 Temperature Transmitter Overview
The Yokogawa YTA110 is a highly reliable, high-performance temperature transmitter designed for universal industrial applications. It accepts inputs from a wide range of thermocouples (TC), RTDs, ohms, or DC millivolts and converts them into a standard 4-20mA DC analog signal with the BRAIN or HART communication protocol. Known for its exceptional stability and durability, the YTA110 is a top choice for critical process measurements.
Key Features & Advantages
- Outstanding Accuracy: Advanced microprocessor technology ensures high-precision temperature readings.
- Dual-Compartment Housing: Prevents moisture ingress into the electronics, making it ideal for harsh, humid, and corrosive environments.
- SIL Certification: SIL 2 certified by TÜV in compliance with IEC 61508, ensuring high safety and reliability in critical plant operations.
- Universal Input: Supports various sensor types, reducing the need for multiple spare parts in your inventory.
Typical Industrial Applications
- Oil & Gas / Refining: Pipeline temperature monitoring and reactor control.
- Chemical & Petrochemical: Ensuring precise temperature ranges for sensitive chemical reactions.
- Power Plants: Boiler and steam temperature measurement.
Why Order the YTA110 From Us?
- 100% Authentic Products: We strictly supply brand-new, genuine Yokogawa transmitters.
- Highly Competitive Pricing: Reduce your procurement costs with our wholesale MRO pricing.
- Global & Fast Delivery: We ship reliably to Southeast Asia (including Indonesia), the Middle East, Europe, and worldwide.
- Dedicated Support: Fast response times and technical assistance for your project needs.
Looking for the best price on the Yokogawa YTA110? Contact our sales team today for a fast, no-obligation quote!
Technical Specifications & Original Features
Part Number: YTA110-EA4DB/KU2
ATEX Intrinsically safe ia, Flameproof approval and Intrinsically safe ic combination
[Intrinsically safe ia approval]
Applicable standard: EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007
Certificate: KEMA 02ATEX1026 X
II 1 G Ex ia IIC T4…T5 Ga Ambient Temerature: -40 to 70?C for T4, -40 to 50?C for T5
Enclosure: IP66/IP67
Supply/Output circuit: Ui=30V, Ii=165mA, Pi=900mW, Ci=20nF, Li=730?H
Input circuit: Uo=9V, Io=40mA, Po=90mW, Co=0.7?F, Lo=10mH
Electrical Connection: 1/2 NPT female and M20 female?
[Flameproof and Dust Ignition Proof Approval]
Applicable Standard: EN 60079-0: 2012+A11: 2013, EN 60079-1: 2007, EN 60079-31:2009
Certificate: KEMA 07ATEX0130
II 2 G Ex d IIC T6/T5 Gb, II 2 D Ex tb IIIC T70?C, T90?C Db
Ambient Temperature for Gas Atmospheres: -40 to 75?C for T6, -40 to 80?C for T5
Ambient Temperature for Dust Atmospheres: -30 to 65?C for T70?C, -30 to 80?C for T90?C
Enclosure: IP66/IP67
Electrical Connection: 1/2 NPT female and M20 female?
[Intrinsically safe ic]
Applicable standard: EN 60079-0:2012, EN 60079-11:2012
II 3 G Ex ic IIC T5…T4 Gc Ambient Temperature: -30 to 70?C for T4, -30 to 50?C for T5
Enclosure: IP66/IP67
Supply/Output circuit: Ui=30V, Ci=28nF, Li=730?H
Input circuit: Uo=9V, Io=40mA, Po=90mW, Co=0.7?F, Lo=10mH
Electrical connection: 1/2 NPT female and M20 female?
- Estimated Lead Time: 10 – 12 Weeks
- Shipping Weight: 3 Kg

Rosemount
Gauge Pressure
Differential Pressure
Absolute Pressure
Rosemount Level Transmitter
Yokogawa
ABB
E+H
HoneyWell
Micro Motion Coriolis
Rosemount
Yokogawa
E+H





Valves&Actuators